MINORFacility Condition
114268 - Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches
MINORSanitation
114252.1 - Lightbulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is nonprepackaged ready-to-eat food, clean equipment, utensils, and linens, or unwrapped single-use
CRITICALPest Activity
114130, 114169 - All new and used equipment and utensils shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program, e.g. NSF,
MINORSanitation
114271 - Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial servi
MINORSanitation
114192, 113953 - The water supply shall be from a water system approved by the local enforcement agency. , 114099 - Sink compartments shall be large enough to accommodate the immersion of the largest
MINORPlumbing & Waste
114193, 114193.1, 114269 - An air gap between the water supply inlet and the flood level rim of the plumbing fixture shall be at least twice the diameter of the water supply inlet and may not be less
SERIOUSSanitation
114256 - Lockers or other suitable facilities shall be located in a designated room or area where contamination of food, equipment, utensils, linens, and single-use articles cannot occur
MINORFacility Condition
114130, 114169 - Floor-mounted equipment that is not easily movable shall be sealed to the floor
MINORSanitation
114271(d) - Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed so as to facilitate cleaning
MINOROther
114130, 114169 - All equipment shall be installed on castors, six (6) inch high round metal legs, or on a minimum four (4) inch high curb or pedestal with a continuously coved base at the juncture
MINORFacility Condition
114193, 114193.1, 114269 - Floor surfaces shall be sloped 1:50 to the floor drains
MINORSanitation
114268 - The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, tra
MINORSanitation
114279, 114281, 114282 - At least one curbed cleaning facility or janitorial sink equipped with hot and cold water and a drain shall be provided and conveniently located
MINORFacility Condition
114193, 114193.1, 114269 - Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration unit
MINORFood Storage & Handling
114244, 114245 - Provide a floor plan showing the path-of-travel to the refuse storage area
MINOROther
Violation noted (details not available)
MINOROther
Violation noted (details not available)