Sanitation
114271 - Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial servi
Other
113953, 113953(b) - Hand sinks shall be sufficient in number and conveniently located so as to be accessible at all times
Facility Condition
114268 - Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches
Facility Condition
114060 - Food on display shall be protected from contamination by approved a sneeze guard (e.g. vertical glass sneezeguard 60" Above Finished Floor)
Food Temperature
114130, 114169 - All new and used equipment and utensils shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program, e.g. NSF,
Facility Condition
114193, 114193.1, 114269 - Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration unit
Sanitation
114099 - Provide a 3-compartment sink with two integral metal drainboards for manually washing, rinsing, and sanitizing equipment and utensils
Other
114130, 114169 - All equipment shall be installed on castors, six (6) inch high round metal legs, or on a minimum four (4) inch high curb or pedestal with a continuously coved base at the juncture
Food Storage & Handling
114244, 114245 - Provide a floor plan showing the path-of-travel to the refuse storage area
Sanitation
114268 - The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, tra
Pest Activity
114192, 113953 - The water supply shall be from a water system approved by the local enforcement agency. , 114266, 114257, 114257.1, 114259 - A food facility shall at all times be constructed, equippe
Plumbing & Waste
114193, 114193.1, 114269 - An air gap between the water supply inlet and the flood level rim of the plumbing fixture shall be at least twice the diameter of the water supply inlet and may not be less
Other
Violation noted (details not available)
Other
Violation noted (details not available)